email
email
Рус Eng
email
8-800-222-14-19
email
info@elmetro.ru
  • About us
    History Mission Reviews Production Publications Licenses Career
    • History
    • Mission
    • Reviews
    • Production
    • Publications
    • Licenses
    • Career
  • Products
    Flowmeters Videographic recorders Electric equipment Metrological equipment Metrology stands Level meters and switches
    • Flowmeters
    • Videographic recorders
    • Electric equipment
    • Metrological equipment
    • Metrology stands
    • Level meters and switches
  • Engineering
    Metrological engineering Project Engineering Installation supervision and commissioning Verification of SI Repairs
    • Metrological engineering
    • Project Engineering
    • Installation supervision and commissioning
    • Verification of SI
    • Repairs
  • News
  • Support
    Support service
    • Support service
  • Partners
  • Contact us
Flowmeters
Videographic recorders
Electric equipment
Metrological equipment
Metrology stands
Level meters and switches
    Download Catalog (26,3 Mb)
    Equipment list
    • ELMETRO-RPU
    • ELMETRO-VSPU
      • ELMETRO-RPU

        ELMETRO-RPU
        Description
        Characteristics
        Documents
        Learn More

        ELMETRO-RPU is FMCW microprocessor-controlled radar with digital signal processing that continuously measures the level, displays readings on a liquid crystal display and transmits them to the upper-level system using standardized industrial communication protocols. A computer with an interface converter connected to it, a programmable logic controller can act as a top-level system.

        Medium

        Liquid

        Solid

        Range, m

        Up to 30 m

        Accuracy, mm

        ±1

        ±3

        ±5

        ±10

        Working environment (process) temperature, ºC

        -40…+80

        -200…+80

        -40…+200

        Working environment (process) pressure, MPa

        -0,1…0,3

        -0,1…1,6

        -0,1…4,0

        Dust and moisture protection

        IP67 by GOST 14254

        Explosion proof type

        absent (for general industrial versions)
        1Ex d IIC T6 ... T3 Gb X and Ex tb IIIC T6 ... T3 Db
        Ga / Gb Ex d IIC T6 ... T3 X and Da / Db Ex ta / tb IIIC T6 ... T3

        Antennas

        Horn

        Rod

        Lense

        Output signals

        4-20mA (active)

        HART (version 7)

        Modbus RTU (RS-485)

        Bluetooth 5

        Ambient air temperature, ºС

        -40…+80

        -50…+80

        -60…+80

        Power supply

        18…36 V DC

        195…265 V AC 50 Hz or 230…370 V DC

        Process connection

        Thread

        Flanges by GOST 33259-2015

        Documentation:

        • User manual
        • Questionnaire
        • Методика поверки

        Certificates:

        • Certificate SI
        • Metological type dessciption
        • Certificate of compliance with the requirements of TR CU 012/2011 ("On the safety of equipment for work in explosive environment")
        • Declaration of conformity with the requirements of TR CU 020/2011 ("Electromagnetic compatibility of technical equipment")
        • Declaration of conformity with the requirements of TR CU 004/2011 ("On the safety of low-voltage equipment")
        • Declaration of conformity with the requirements of TR CU 004/2011 ("On the safety of low-voltage equipment")

        Software:

        • PC softare RadarConfig

      • ELMETRO-VSPU

        ELMETRO-VSPU
        Description
        Characteristics
        Documents
        Learn More

        Vibrating level switches ELMETRO-VSPU are designed for monitoring and signaling the limit levels of liquids in open or closed, including pressurized tanks in technological installations, the presence of liquid in pipelines.

        The type of alarm is determined by the position of the alarm in the tank, pipeline, etc. The operating position of the signaling device is any, providing control of the level or the presence of the working medium.

        Medium type

        Liquid/Air

        Liquid/Liquid

        Medium density, g/sm3

        From 0.4 to 1.6 - "light" media

        From 0.7 to 2.5 - "heavy" media

        Temperature of the controlled environment (process)

        -50…+150 ºС,

        Maximum pressure of controlled environment (process), MPa

        6,3

        Medium viscosity, mm2/s

        up to 10 000

        Dust and moisture protection

        IP67 by GOST 14254

        Explosion proof types 2)

        absent (for general industrial versions)
        0 Ex ia IIC T6..T3 Ga X
        1 Ex d ia IIC T6 ... T3 Gb X
        Ga / Gb Ex ia / d IIC T6 ... T3 X

        Output test function

        To check the change in the state of the output signal, by a button (with the cover removed) or by means of a magnet (with the cover installed), can be switched off.

        Resistance to power failure, duration

        maximum 50 ms

        Configuration with DIP switches

        MIN / MAX; density threshold, output test enable, response delay, Alarm level, output duplication functions.

        Ambient temperature,

        Tа 2),4)

        -40…+80 ºС

        -50…+80 ºС

        Power supply

        max. 89 VA (Two-wire AC output)

        max. 0.6 W (Transistor output 2 x PNP)

        max.  1.3 W (Relay output 2 x SPDT)

        max. 0.86 W (Two-wire DC 8 / 16mA output)

        max. 0.09 W  (Two-wire NAMUR output)

        Accuracy of water level detection at +25 ºС after operating time 240 hours, no more, mm 5)

        ±1

        • The level switches correspond to the C2 execution group in accordance with GOST R 52931-2008, but for operation at an ambient temperature of minus 40 (from -50C with option E) to plus 80 ° C, with an upper value of 100% relative humidity at 30 ° C and lower temperatures with moisture condensation.
        • In terms of resistance and durability to atmospheric pressure, the signaling devices correspond to the group of executions P2 in accordance with GOST R 52931: from 84.0 to 106.7 kPa.
        • In terms of resistance and durability to the effects of sinusoidal vibration, the signaling devices correspond to the V1, N2 execution groups in accordance with GOST R 52931.
        • Signaling devices are resistant to any environment that does not cause corrosion of steel grade 12X18H10T in accordance with GOST 5949.

        Documentation:

        • User manual
        • Questionnaire

        Certificates:

        • Certificate of conformity with the requirements of TR TS 012/2011 ("On the safety of equipment for work in explosive atmospheres") 
        • Certificate of conformity with the requirements of TR TS 020/2011 ("Electromagnetic compatibility of technical means")
        • Certificate of conformity with the requirements of TR TS 004/2011 ("About the safety of low voltage equipment")
        • Certificate of conformity with the requirements of TR TS 032/2013 ("About the safety of high pressure equipment")
        • SIL2 safety certificate

        Software:

    Russia, Chelyabinsk
    29 Komsomolsky avenue

    8-800-222-14-19
    info@elmetro.ru

    © ElMetro 2008-2021

    Privacy policy